Product Details:
Brand | Weiber |
Temperature Range | +10 deg C to +70 deg C |
Light Source | Water Cooled Xenon Lamp (MHG optional) |
Temperature Uniformity | + 3 deg C |
Distance Between Test Product And Lamp Surface | 50 +- 2mm |
Temperature Control | The Temperature Is Efficiently Controlled By Plc Based Hmi (Human Machine Interface) |
Humidity Range | Up to 95% RH,+/-5% |
Light Intensity On Specimen Surface | 500 - 1200 W/m2 |
UV Wavelength | 290nm-400nm,UV-A,UV-B |
Spectrum Wavelength | 280nm-800nm |
Light Uniformity | Within +/- 5% |
Rising Wave Length | 320 nm |
Light Intensity Control | 300 to 400 nm |
Specimen Rotating Frame | 2 RPM |
Xenon is one of the noble gases and is a major component of arc lamps and flash lamp and it also has its importance in general anesthetics. One of the major applications of xenon lamp is that it can be used in research applications to simulate the sunlight.
Weiber walk in xenon lamp chamber uses xenon lamp to simulate the whole sunlight spectrum that can produce many destructive effects on the products. This simulation environment provided in the chamber is used to test the resistance of various manufactured products towards these destructive conditions. This chamber is used for quality control, product development and scientific researches and many more. With a variety of models and options, you can customize your chamber to fit your testing needs. With walk in option you have a facility to test your product in bulk quantity and even for the products which are larger in size. This chamber also known as Uv Test Chamber and Xenon Lamp Weather Resistance Test Chamber.
Weiber xenon test chambers are easy to install, easy to program and easy to operate. Specimen mounting and evaluations are simplified with specially designed specimen holders. All models are completely automated and can operate continuously, 24 hours per day, 7 days per week, without supervision. The testers are smart enough to alert you to problems they may encounter during testing.
Special Features:
Three categories of optical filters are available to simulate variety of service environments.
Daylight filters are used to simulate direct sunlight.They provide the best correlation to natural outdoor exposures for most applications. Materials thatare typically used outdoors like roofing or exterior coatings should be tested using daylight filters.
Window glass filters produce spectra equivalent to sunlight coming through window glass. This spectrum can also simulate other indoor lighting suchas the harsh lighting found in a typical commercial or office environment. Window glass filters are used for indoor materials such as printing materials or textiles
Extended UV filters allow excess UV, below the normal cut-on of natural sunlight.They are used to produce faster or more severe test results. Extended UV filters arespecified in some automotive test methods and are sometimes used for aerospace applications
All Q-Sun models control specimen temperature with a Black Panel ora Black Standard sensor. Due to its black coating it absorbs all wavelength uniformly, it provides an estimate of the maximum temperature of the specimen inside the chamber.
The black panel temperature can be set anywhere between 25oC and 120oC depending upon the irradiance level, lamp age, ambient room temperature, black panel sensor and specific tester model. Chamber Air Temperature can also be controlled simultaneously with Black Panel Temperature to give the ultimate control of specimen temperature.
Product Details:
Brand | Weiber |
Temperature Range | +10 deg C to +70 deg C |
Weight | 190-233 kg |
Light Source | Water Cooled Xenon Lamp/ Air cooled xenon lamp |
Temperature Uniformity | + 3 deg C |
Distance Between Test Product And Lamp Surface | 50 +- 2mm |
Temperature Control | The Temperature Is Efficiently Controlled By Plc Based Hmi (Human Machine Interface) Interactive Con |
Working Size | 2 x 2 x 3 feet / 3 x 3 x 4 feet |
Humidity Range | Up to 95% RH,+/-5% |
Light Intensity on Specimen Surface | 500 - 1200 W/m2 |
UV Wavelength | 290nm-400nm,UV-A,UV-B |
Spectrum Wavelength | 280nm-800nm |
Light Uniformity | Within +/- 5% |
Rising Wave Length | 320 nm |
Light Intensity Control | 300 to 400 nm |
Specimen Rotating Frame | 2 RPM |
Weiber xenon lamp chamber uses xenon lamp to simulate the whole sunlight spectrum that can produce many destructive effects on the products. This simulation environment provided in the chamber is used to test the resistance of various manufactured products towards these destructive conditions. This chamber is used for quality control, product development and scientific researches and many more. With a variety of models and options, you can customize your chamber to fit your testing needs. Reach in chambers provide a compact testing area for small applications. These are easy to install, transport and occupies less space.
Special Features:
Three categories of optical filters are available to simulate variety of service environments.
Daylight filters are used to simulate direct sunlight.They provide the best correlation to natural outdoor exposures for most applications. Materials thatare typically used outdoors like roofing or exterior coatings should be tested using daylight filters.
Window glass filters produce spectra equivalent to sunlight coming through window glass. This spectrum can also simulate other indoor lighting suchas the harsh lighting found in a typical commercial or office environment. Window glass filters are used for indoor materials such as printing materials or textiles
Extended UV filters allow excess UV, below the normal cut-on of natural sunlight.They are used to produce faster or more severe test results. Extended UV filters arespecified in some automotive test methods and are sometimes used for aerospace applications
All Q-Sun models control specimen temperature with a Black Panel ora Black Standard sensor. Due to its black coating it absorbs all wavelength uniformly, it provides an estimate of the maximum temperature of the specimen inside the chamber.
The black panel temperature can be set anywhere between 25oC and 120oC depending upon the irradiance level, lamp age, ambient room temperature, black panel sensor and specific tester model. Chamber Air Temperature can also be controlled simultaneously with Black Panel Temperature to give the ultimate control of specimen temperature.
Outdoor moisture attack issimulated via a pure water spray.Two nozzles are located in thetop of the chamber. Spray canbe programmed to operate during either the dark or light cycle.
In addition to oxygenation, spray can be useful for creating thermal shock and/or mechanical erosion.
The Solar Eye system constantlymonitors and controls lamp outputto assure precise light exposureand to maximize repeatability and reproducibility of test results.Irradiance control is available at 340 nm, 420 nm or TUV.
4.6/5
Reviewed by 11 Users
Most Relevant Reviews