Product Details:
Brand | Weiber |
Air Flow | Unidirectional |
Frequency | 50 Hz |
Illumination | Fluorescent Light Illumination Greater Than 800 Lux |
Cabinet Construction | Industrial Grade Mica Clad Wooden Board / Ms / SS- 304 |
Nominal Voltage | 220-230 volts |
Noise Pressure | 54dB |
Pre Filter Unit | Washable Pre Filter Unit |
Power Requirements | 500-750 watts |
Weiber stainless steel Laminar Air Flow Systems are conceptualized to provide clean workspace bathed in high efficiency perfect air which is free from any kind of particulate contamination or impurities. Our range is also in accordance with the set industry standards and made available in customized specifications as per the clients’ requirements.
Weiber mobile and portable benches have been developed in co-operation with a variety of end users, resulting in an ergonomically justified concept. These developments eventually lead to an optimal sitting / working position. Moreover microprocessor based laminar flow provides sterile environment for sample preparation, media handling, operation theatres and various other medical applications. The system also known as Laminar Air Flow System for Instrument Preparation.
Standards Compiled:
Special Features:
Operating Principle:
The mono direction of air is directed away from the specimen and towards the user, giving ultimate protection to the product from all form of contamination induced by diffusion of contaminated air from the outside.
Construction Details:
The advanced and modular laminar air flows’ are constructed from all white seamless polypropylene or mild steel cabinet duly epoxy coated. The custom made work table is made of thick board which is sunmica clad at top or S. S Table top will be provided as optional accessories. Moreover the floor standing unit is fitted with pre-filter and is made to pass through highly effective HEPA (High Efficiency Particular Air) filter having efficiency rating as high as 99.997%.
Illumination - The working is illuminated by fluorescent lightings fitted to the unit along with germicidal ultra violet light that ensures high standard of cleanliness in our customized equipments.
Noise Level - Weiber automatic laminar air flow systems are designed to ensure minimum possible noise and vibration levels.
Applications:
Product Details:
Brand | Weiber |
Weight | 76.5-115 kg approx. |
Laminar Airflow Velocity | 0.275 - 0.325 m/s (54-64 fpm) |
Sound Emission | 63dB |
Fluorescent Lamps Intensity | 800 Lux |
Controller | Microprocessor Control |
Load | 1-3A |
Nominal Power | 136-260 W |
Special Features:
Operating Principle:
Polymerase Chain Reaction (PCR) is a process where millions of copies of DNA are amplified from a single copy, or low copy number template. This reaction is used in all laboratories working with DNA and RNA.
Because of the high copy number generated during PCR, it is essential to prevent possible contamination of the PCR reaction.Reagents should be prepared in the reagent preparation area and transferred to the sample preparation area, through a pass box, or inside closed containers. After preparation of the final reaction mix, the tubes should be transferred to the amplification area, again through a pass box or in a closed container. The PCR amplification and results analysis takes place in this area.
To guarantee contaminant-free samples, it is essential to work in an environment where the air quality is controlled. This should form part of the equipment in the sample preparation area.
Product Details:
Brand | Weiber |
Air Flow | Unidirectional |
Illumination | Fluorescent Light Illumination Greater Than 800 Lux |
Frequency | 50Hz |
Cabinet Construction | SS-304/PCRC SHEET |
Nominal Voltage | 220-230 Volts |
Noise Pressure | 54dB |
Pre Filter Unit | Washable Pre Filter Unit |
Power Requirements | 500-750 watts |
WEIBER Vertical Laminar Air Flow are conceptualized to provide a work area completely bathed in high efficiency perfect air, which is free from any kind of particulate contamination or impurities. These units are ideally suited in all the applications, requiring protection of biological specimens or products from the possible contamination during the process or test. Our Laminar Air Flow Bench is fast gaining popularity in other fields, such as pharmaceutical production, electronic industries and various other manufacturing applications.
A vertical clean bench pushes air through a HEPA filter which is located at the top of enclosure. The air is directed downward onto the work surface at a constant speed.
It is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.
A vertical clean bench, on the other hand, offers a pivoting glass sash as a safety measure. This sash offers personal protection and a physical barrier when working with chemicals. Vertical clean benches are common place in microbiology, forensic, biotech and many other industries, which utilizes them during procedures that require clean work area.
Standards Compiled:
Special Features:
Product Details:
Brand | Weiber |
Air Flow | Unidirectional |
Frequency | 50Hz |
Illumination | Fluorescent Light Illumination Greater Than 800 Lux |
Cabinet Construction | SS-304/PCRC SHEET |
Nominal Voltage | 220-230 volts |
Noise Pressure | 54dB |
Pre Filter Unit | Washable Pre Filter Unit |
Power Requirements | 500-750 watts |
WEIBER Horizontal Laminar Flow workstations are designed to protect the product within the work area from airborne particulates in the ambient air. The regulated efflux of custom made laminar airflow supplies the work zone with ISO Class 5 air cleanliness to offer the best product production by a clean bench in the industry. The Horizontal Laminar Flow workstations pushes the air through a HEPA filter and directs the filtered air horizontally over the work surface at a constant speed, toward the operator.
Our versatile unit is useful for various works that require maintenance of the cleanness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, entomology, pharmacy, agriculture sector, seed science, veterinary science.
Horizontal Laminar Air Flow generally have a taller and therefore a larger loading and working area. This allows for instruments, like microscopes to be placed inside. They are typically the preferred selection for plant tissue culture, media plate preparation, electronics inspection, medical device assembly and pharmacy drug preparation. Because they do not provide protection to the user, they should not be used in conjunction with biohazardous material, toxins or radionuclides. One of the key benefits is the absence of a sash, which is an advantage when placing instruments and equipment inside. This cabinet also known as Laminar Air Flow Cabinet.
Standards Compiled:
Special Features:
Product Details:
Brand | Weiber |
Air Flow | Unidirectional |
Illumination | Fluorescent Light Illumination Greater Than 800 Lux |
Frequency | 630x538x550 mm |
Cabinet Construction | SS-304 |
Nominal Voltage | 220-230 volts |
Noise Pressure | 54dB |
Pre Filter Unit | Washable Pre Filter Unit |
Power Requirements | 500-750 watts |
Weiber Recirculation Laminar Air Flow System uses internal air by means of recirculation.These systems are ideal solution for laboratory testing, low risk pharmaceutical compounding and more. They are most suitable for bacteriological, toxicology, where the presence of highly air borne particles, bacterial and viral need to be controlled to provide clean working conditions. The system also known as Ceiling Laminar Air Flow.
Our unit has unique airflow system that ensures consistent airflow and HEPA filter loading, significantly improving filter life. It provides reasonable user protection with its b air barrier containment thus, reducing pharmacists or operators fatigue which in turn increases user safety.
Special Features:
Construction Details:
Applications:
Product Details:
Size | 2800X2800 mm |
Brand | Weiber |
Air Flow | Unidirectional |
Illumination | Fluorescent Light Illumination Greater Than 800 Lux |
Frequency | 50 Hz |
Cabinet Construction | Industrial Grade Mica Clad Wooden Board / Ms / SS- 304 |
Nominal Voltage | 220-230 Volts |
Noise Pressure | 54dB |
Pre Filter Unit | Washable Pre Filter Unit |
Power Requirements | 500-750 watts |
Model No | ACM-921TZ |
The Medical Laminar Air Flow System provides a safe and clean environment for compounding of hazardous and sterile drug preparations. The special design of our versatile laminar flow cabinet allows safe manipulation of sterile products with an inward air barrier that increases operator safety.
The mild steel constructed Hospital Laminar Air Flow System bench can be used for a wide variety of applications including sterility testing, cell culture, molecular biology, veterinary science, drug preparation, operation theatres, PCR (in active mode with UV light and timer option), food industry and assembly of optical and electronic components.
Air supplied to this Medical Laminar Air Flow System is air from outside, made up by means of filtering, cooling, heating and humidifying to the required conditions.
Special Features:
Construction Details:
Constructed of Corrosive Resistant Polypropylene, Epoxy Painted Steel, 304 or 316 Stainless Steel.
Noise Level - two zone laminar air flow system are designed to ensure minimum possible noise and vibration levels.
Illumination - these are provided with adequate illumination at the work table by means of fluorescent lights panel concealed at the upper portion of the unit. This light arrangement conforms to the guidelines laid down in US federal standard. The illumination at the work table is approx> 800 lux.
Applications:
4.6/5